Powerful Scale and Corrosion Inhibitor For Boiler Water
Powerful Scale and Corrosion Inhibitor for Boiler Water
1000-NR is a blend of selected phosphates which react to precipitate calcium hardness in the boiler as a sludge and prevent the formation of hard calcium carbonate, sulfate, and/or silicate scale. The finely-divided, non-adherent calcium phosphate sludge remains suspended in the boiler water until removed via the blowdown.
1000-NR contains the best and most highly concentrated phosphates to assure maximum results with a minimum of treatment.
Containing oxygen scavenger polymer-based technology, 1000-NR provides very efficient corrosion inhibition effect and prevents iron losses, pitting, and pinholes up to the maximum extent.
1000-NR dosages depend upon many factors, including the chemical characteristics of the makeup water, boiler operations, percentage of condensate return, etc.
Individual dosage recommendations are made for each installation by your Maxon representative, based on his survey. Dosage is controlled by various water quality color comparison tests.
1000-NR is compatible with most boiler water chemicals and can be blended with them in the treatment feed tank. 1000-NR may be fed in several ways, depending upon the makeup water characteristics and the boiler operations.
Specific recommendations will be made by your Maxon representative for each installation.
Store in a cool, dry place. Store in a tightly closed container at moderate temperature. Do not freeze.
Wash thoroughly after handling. Use only in a well-ventilated area. Avoid contact with skin, eyes, and clothing. Do not inhale or ingest.
1000-NR comes in containers conforming to Performance Oriented Packaging Specifications, in the following sizes:
On special request: 1 metric ton IBC cage tanks
Material Safety Data Sheet
According to Regulation (EC) No 1907/2006, Annex II
Appearance and Color: Dark brown viscous liquid
Odor: No specific odor
Solubility in Water: Completely miscible
Specific Gravity: ~1.15-1.25
pH: 11.5-12.5
% Volatile by Volume @ 21°C (70°F): NDA
Boiling Point: 103°C
Melting Point: NDA
Vapor Density (Air=1): NDA
Vapor Pressure (mm Hg): NDA
Evaporation Rate (Bu. Acetate=1): NDA
Chemical Name: 1000-NR
Product Code: BWT-10N
Composition Identity: Phosphate, Polycarboxylates, Sulphates
CAS Number: Not applicable to mixtures
Chemical Formula: Mixture / Polymeric mixture
Identified Usage: Boiler water treatment (Anti-corrosion & Anti-scale)
Technical Principal:
Maxon UK
Emergency Overview:
Prolonged skin contact can be destructive to tissue. Potential eye damage from contact.
Signs and Symptoms of Acute Overexposure:
Irritating. Inhalation of mists from the product may cause irritation. May be harmful if swallowed.
Signs and Symptoms of Chronic Overexposure:
Prolonged skin contact will cause irritation, defatting, and possible dermatitis. Wash with soap and water. See a physician if irritation occurs. Remove and wash contaminated clothing before reuse.
Medical Conditions Generally Aggravated by Exposure:
None known.
Stability: Product is stable under normal conditions.
Hazardous Decomposition Products: Sulfur dioxide, Sulfide residues.
Hazardous Polymerization: Will not occur.
Incompatibility: Acids, organic materials, alcohols, nitro compounds, halogens, acid anhydrides.
Conditions to Avoid: Incompatible chemicals.
RTECS:
CAS# 7758-29-4: YK4500000
CAS# 7601-54-9: TC9490000
CAS# 68131-31-7: 016142000
CAS# 1310-73-2: WB4900000
LC50/LD50:
Carcinogenicity: Ingredients not listed by ACGIH, IARC, NIOSH, NTR, or OSHA.
Dike spillage, pump to drums, or collect with absorbent material and place in plastic or stainless steel containers. May be washed to the sewer.
Oxygen Scavenger, Scale Preventor & Sludge Conditioner for Boiler Water (Powder Form)
1000-SQP is a free-flowing, powder-form, corrosion-causing catalyzed and decharacterized oxygen scavenging formula that combines chemically with dissolved oxygen in feedwater or in the boiler to inhibit the formation of oxygen-induced corrosion, including pitting. The effective combination of Sulfite and Phosphate-based polymers, proven effective in 1000-SQP, is here supplemented with sodium-based lignosulphite polymer formula, which contributes less than one percent sodium hydroxide to the finished formula.
1000-SQP not only provides efficient corrosion inhibition but also conditions mobile sludge levels for scale reduction in normal ranges.
1000-SQP dosages depend upon many factors, including the chemical characteristics of the makeup water, boiler operations, percentage of condensate return, etc. Individual dosage recommendations are made for each installation by your Maxon representative based on his survey. 1000-SQP dosage will vary considerably depending upon the feedwater temperature, type of boiler operation, type of heater or deaerator, air leakage into the system, etc.
1000-SQP is best fed continuously by chemical metering pumps into the deaerator storage section. However, the ordinary boiler treatment feeding methods, such as simple shot feeders, can be used with diminished effectiveness. Methods can be adopted depending on feasibility for the operator.
Store in a cool, dry place. Store in a tightly closed container at a moderate temperature; do not blend. Wash thoroughly after handling. Use only in a well-ventilated area. Avoid contact with skin, eyes, and clothing. Do not inhale or ingest.
1000-SQP comes in containers conforming to Performance-Oriented Packaging Specifications, in the following sizes:
Material Safety Data Sheet
According to Regulation (EC) No 1907/2006, Annex II
Appearance and Color: White powder
Odor: Slight Odour
Solubility in Water: Completely miscible
Specific Gravity: NA
pH: 10-11.5
% volatile by volume @ 21C (70F): NDA
Boiling Point: NA
Melting Point: NDA
Vapor Density (Air=1): NDA
Vapor Pressure (mm Hg): NDA
Evaporation Rate (Bu. Acetate=1): NDA
Chemical Name: 1000-SQP
Product Code: BWT-14P
Composition Identity: Phosphate, Sulphonates, Sulphites, Others
CAS Number: Not applicable to grain blend
Chemical Formula: Mixture / grain blend
Identified Usage: Boiler water Treatment
Oxygen scavenger, Anti-corrosion & anti-scalant
Emergency Overview: Prolonged skin contact can be destructive to tissue. Potential eye & lung damage from contact.
Signs and Symptoms of Acute Overexposure: Irritating. Inhalation of fine powder residues from the product could cause severe irritation. May be harmful if swallowed.
Signs and Symptoms of Chronic Overexposure: Prolonged skin contact will cause irritation, slight lesions, and defatting. Wash with soap and water. See a physician if irritation occurs. Remove and wash contaminated clothing before reuse.
Medical Conditions Generally Aggravated by Exposure: Ingestion may cause severe allergic reaction.
Inhalation: Remove patient to fresh air. Get prompt medical attention.
Ingestion: Give patient 2 – 4 glasses of water or milk to dilute the product. Induce vomiting by tickling the back of the throat.
Skin Contact: Remove contaminated clothing and footwear. Wash skin with soap and water. Wash clothing before reuse.
Eye Contact: Immediately flush eyes with water for 15 minutes. Get medical attention.
Note to Physician: None
Stability: Product is stable under normal conditions.
Hazardous Decomposition Products: Sulphur dioxide gas, sodium sulfide residue.
Hazardous Polymerization: Will not occur.
Incompatibility: Acids – nitro compounds – Strong Oxidizers.
Conditions to Avoid: Incompatible chemicals.
RTECS:
CAS# 7757-83-7: WE2150000 / CAS# 68131-31-7: 016142000 / CAS# 10124-43-3: GG5100000 / CAS# 1310-73-2: WB4900000
LD50/LC50:
Carcinogenicity: Ingredients not listed by ACGIH, IARC, NIOSH, NTR, or OSHA.
Dike spillage, pump to drums; or collect with absorbent material and place in plastic or stainless steel containers. May be washed to the sewer.
Phosphate & Polymer Based Scale and Corrosion Inhibitor for Low to Medium Pressure Boiler
1000-JV is a blend of selected phosphates that are polymerized for reaction to precipitate calcium hardness in the boiler as a sludge and prevent the formation of hard calcium carbonate, sulfate, and/or silicate scale. The finely divided, non-adherent calcium phosphate sludge remains suspended in the boiler water until removed via the blowdown. 1000-JV contains the best and highly concentrated hypo phosphates to assure maximum results with a minimum of treatment.
Containing oxygen scavenger polymer-based technology, 1000-JV provides very efficient corrosion inhibition and prevents iron losses, pitting, and pinholes to the maximum extent.
1000-JV dosages depend upon many factors, including the chemical characteristics of the makeup water, boiler operations, percentage of condensate return, etc. Individual dosage recommendations are made for each installation by your Maxon representative, based on his survey. Dosage is controlled by various water quality color comparison tests.
1000-JV is compatible with most boiler water chemicals and can be blended with them in the treatment feed tank. 1000-JV may be fed in a number of ways, depending upon the makeup water characteristics and the boiler operations. Specific recommendations will be made by your Maxon representative for each installation.
Store in a cool, dry place. Store in a tightly closed container at a moderate temperature, do not freeze. Wash thoroughly after handling. Use only in a well-ventilated area. Avoid contact with skin, eyes, and clothing. Do not inhale or ingest.
1000-JV comes in containers conforming to Performance-Oriented Packaging Specifications, in the following sizes:
Here is the extracted text with Heading Size 4 formatting:
Material Safety Data Sheet
According to Regulation (EC) No 1907/2006, Annex II
Appearance and Color: Dark brown, viscous liquid
Odor: Slight odor
Solubility in Water: Completely miscible
Specific Gravity: 1.1-1.3
pH: 10-11.5
% Volatile by Volume @ 21°C (70°F): NDA
Boiling Point: NDA
Melting Point: NDA
Vapor Density (Air=1): NDA
Vapor Pressure (mm Hg): NDA
Evaporation Rate (Bu. Acetate=1): NDA
Chemical Name: 1000-JV
Product Code: BWT-14P
Composition Identity: Phosphate, Polyphosphate, Sulphates
CAS Number: Not applicable to blend
Chemical Formula: Mixture / grain blend
Identified Usage: Boiler water treatment – Oxygen scavenger, Anti-corrosion & Anti-scalant
Emergency Overview: Prolonged skin contact can be destructive to tissue. Potential damage to eyes and lungs from contact.
Signs and Symptoms of Acute Overexposure: Irritating. Inhalation of mist/fine residues from the product can cause respiratory irritation. May be harmful if swallowed.
Signs and Symptoms of Chronic Overexposure: Prolonged skin contact can cause slight lesions, slight dermatitis, and burns. Wash with soap and water. See a physician if irritation persists. Remove and wash contaminated clothing before reuse.
Medical Conditions Generally Aggravated by Exposure: None known.
Inhalation: Remove the patient to fresh air. Get prompt medical attention.
Ingestion: Give the patient 2 – 4 glasses of water or milk to dilute the product. Induce vomiting by tickling the back of the throat. Get medical attention immediately.
Skin Contact: Remove contaminated clothing and footwear. Wash skin with soap and water. Wash clothing before reuse.
Eye Contact: Immediately flush eyes with water for 15 minutes. Get medical attention.
Note to Physician: None.
Stability: Product is stable under normal conditions.
Hazardous Decomposition Products: Sulfur dioxide gas, sulfide residues.
Hazardous Polymerization: Will not occur.
Incompatibility: Acids, nitro compounds, halogens, acid anhydrides.
Conditions to Avoid: Incompatible chemicals.
RTECS: CAS# 7757-83-7: WE2150000 / CAS# 68131-31-7: 016142000 / CAS# 10124-43-3: GG5100000 / CAS# 1310-73-2: WB4900000
LD50/LC50:
Carcinogenicity: Ingredients not listed by ACGIH, IARC, NIOSH, NTR, or OSHA.
Spillage: Pump into drums or collect with absorbent material and place in plastic or stainless-steel containers. May be washed to the sewer.